OBEX CORTEX 0530FR Class B VCL is an airtight and vapour-tight membrane layer used to increase vapour and airtightness and improve moisture management and energy efficiency.
OBEX CORTEX 0530FR Class B VCL membrane has excellent air and vapour-tightness properties which make it ideally suited to improving the airtightness, moisture management and energy efficiency of buildings.
It is installed on the warm side of the insulation and provides an air and vapour-tight barrier, preventing warm air and moisture from passing through the external wall and forming interstitial or surface condensation within the cavity.
The VCL Membrane is normally bonded to the steel framing with OBEX CORTEX Double-Sided Tape before the plasterboard layer is applied. Applications may vary depending on the construction build up. The OBEX Technical team can help with any application queries.
The membrane is installed using the CORTEX 0825 Installation Kit which includes 2 rolls of CORTEX 0824FR Double-Sided Tape and 6 rolls of single sided CORTEX 0823FR UV Façade Tape.
Packaging
Individual Rolls
Technical Specs
Harmonised Standard
EN 13984
Fire Classification | EN 13501-1
B-s1,d0
Water-Tightness | EN 1928
Pass - 2kPa for 24 hours
Water-Tightness after UV & Heat ageing | EN 1296 & EN 1297
Pass - 2kPa for 24 hours
Resistance to Air Penetration | EN 12114
Net Leakage: 0m³/h/m² (+/- 100 Pa)
Sd Value | EN 1931
100m
Vapour Resistance | EN 1931
500MNs/g
Water Vapour Transmission | EN 1931
416666 μ
Tensile Strength | EN 12311-2
Longitudinal: 160 N/50mm
Transverse: 155 N/50mm
Tensile Strength after UV & Heat ageing | EN 1296 & EN 1297
Longitudinal: 130 N/50mm
Transverse: 140 N/50mm
Tear Strength | EN 12310-1
142N
Product Data Sheet Links
Technical Data Sheet
Safety Data Sheet
Install Guide
DoP
The above information is based on current test data, health and safety information and application instructions supplied by our suppliers and manufacturers of the products. It is supplied for guidance and to the best of our knowledge is true and accurate. Customers should satisfy themselves to the suitability of the products in its intended use and no guarantee is given or implied as the conditions of actual use are beyond our control. If in doubt the customer should consult the designer of the project or the local building control.