Carboline carbozinc 11 Green - 4L Kit
Carboline carbozinc 11 Green - 4L Kit
Time-tested corrosion resistant coating that provides excellent galvanic corrosion protection to steel in some of the harshest environments. For over five decades, carbozinc 11 has been the industry standard for high-performance inorganic zinc protection on steel structures worldwide.
Product Features
- Meets Class B slip co-efficient and creep testing criteria for use on faying surfaces.
- Rapid cure. Dry to handle in 45 minutes at 60°F (16°C) and 50% relative humidity
- Low temperature cure down to 0°F (-18°C)
- High zinc loading
- Meets FDA requirements
- Zinc supplied meets ASTM D520 (Type II)*
- Meets SSPC Paint 20 Type I, Level 1 for zinc content
- Very good resistance to salting
- May be applied with standard airless or conventional spray equipment
- VOC compliant in many areas
- Approved MPI #19
Color | Green (0300); Gray (0700) |
Finish | Flat |
Primer | Self-priming. |
Dry Film Thickness | 2 - 3 mils (51 - 76 microns) . Dry film thickness in excess of 6.0 mils (150 microns) is not recommended. |
Solid(s) Content | By Volume 99% +/- 2% Measured in accordance with ASTM D 2697. |
Total Zinc Dust in Dry Film |
y Weight: 85% |
Coverage Rate | 1000 ft2 /gal at 1 mil (24.5 m2 /l at 25 microns) DFT 333 ft2 /gal at 3 mils (8.2 m2 /l at 75 microns) DFT Measured in accordance with ASTM D 2697. Allow for loss in mixing and application. |
VOC Values |
As Supplied : EPA Method 24: 4.0 lbs./gal (479 g/l)
|
Maximum Service Temperature |
Untopcoated |
Topcoats |
Not required for certain exposures. May be topcoated with Armorlast Series inorganic silicate finishes. May also be topcoated with Waterborne Acrylics, Epoxies, Polyurethanes, HighTemperature Silicones and other coatings as recommended by Carboline. Under certain conditions a mist coat may be required to minimize bubbling. |
Data Sheets
carbozinc 11 PDS
carbozinc 11 (Zinc Filler Type II) SDS Part B
carbozinc 11 SDS Part A
carbozinc 11 - Product Brochure
Series Flyer - carbozinc 11
The above information is based on current test data, health and safety information and application instructions supplied by our suppliers and manufacturers of the products. It is supplied for guidance and to the best of our knowledge is true and accurate. Customers should satisfy themselves to the suitability of the products in its intended use and no guarantee is given or implied as the conditions of actual use are beyond our control. If in doubt the customer should consult the designer of the project or the local building control.
Fire Stopping Shop, disclaim any liability for loss, damage or other expense which may arise from the use of this information, data or products refereed to and reserve the right to amend or change any details without notice. This statement does not affect your statuary rights.