Nullifire FS719
FS719 HP Blue for CPVC has been developed specifically for CPVC materials.The product is a distinctive blue colour, for easy visual identification and traceability.
FS719 is a unique sealant used to reinstate the compartment fire performance of compartment lines (walls & floors) which have been breached by CPVC combustible sprinkler systems.Benefits• Up to 2 hours fire resistance -Tested to EN 1366-3• Versatile & easy to apply• Can be used with FB750 Intubatt Coated Batt• Tested in openings up to 365 x 700 mm
• Distinctive blue colour
• 310ml tubes (box of 25)
Note: This product is tested for use only around CPVC pipes. Please refer to the data sheet for application information
Technical data
Usage Guidelines
Preparation
- All installers should have received training on the handling procedures required by the manufacturers of CPVC pipes on their products.
- All surfaces must be clean and sound, free from dirt, grease and any other contamination. Cleaning materials used must be approved & recommended by the CPVC pipes manufacturer.
- Check FS719 specification is suitable for substrate, fire rating, annular space and seal depth.
- We recommend that the surface of substrate temperature be +5°C or above at the time of application. Contact Technical Services for
- advice regarding lower temperature application.
Application
For full application details, refer to product data sheet.
Product Data Sheet Links
FS719 Technical Data Sheet
FS719 Safety Data Sheet
FS719 Double Intubatt Technical Drawing
FS719 Single Intubatt Technical Drawing
FS719 Direct To Substrates Technical Drawing
FS719 Sleeved CPVC Technical Drawing
Specification and Design Guidance Document 2024
Further Assistance
Further assistance or information can be obtained by calling the technical team on 02476 422200.
All orders are usually despatched within 24 hours of receiving cleared payment (Mon–Fri).
The above information is based on current test data, health and safety information and application instructions supplied by our suppliers and manufacturers of the products. It is supplied for guidance and to the best of our knowledge is true and accurate. Customers should satisfy themselves to the suitability of the products in its intended use and no guarantee is given or implied as the conditions of actual use are beyond our control. If in doubt the customer should consult the designer of the project or the local building control.
Fire Stopping Shop, disclaim any liability for loss, damage or other expense which may arise from the use of this information, data or products refereed to and reserve the right to amend or change any details without notice. This statement does not affect your statuary rights.